DESIGN BENTUK DINDING GESER (SHEAR WALL) GEDUNG PERKULIAHAN UIN MAULANA MALIK IBRAHIM TAHAP II PADA FAKULTAS KEDOKTERAN
SHEAR WALL DESIGN OF UIN MAULANA MALIK IBRAHIM LECTURE BUILDING PHASE II AT THE FACULTY OF MEDICINE
Proyek pembangunan Gedung Fakultas Kedokteran Kampus 3 UIN Maliki Malang Tahap II di Batu menghadapi masalah kurangnya sistem peredam gempa. Oleh karena itu, tugas akhir ini bertujuan merancang dinding geser untuk meningkatkan kekakuan dan ketahanan struktur terhadap beban gempa lateral, sesuai SNI 1726:2019. Penelitian kuantitatif ini menggunakan simulasi experimental observation dengan software ETABS untuk menganalisis kinerja struktur, termasuk perioda fundamental, gaya geser dasar, eksentrisitas, simpangan antar tingkat, dan pengaruh P-Delta. Hasilnya menunjukkan bahwa penambahan dinding geser dapat mengurangi displacement hingga dua kali lipat, dan dari bentuk I-WF, L-Shape, dan T-Shape yang diuji, hanya bentuk I-WF yang memenuhi syarat eksentrisitas dan sistem ganda SNI 1726:2019. Meskipun semua bentuk mengalami keretakan di lantai bawah yang memerlukan penyesuaian stiffness modifier, bentuk I-WF terbukti paling efektif. Kesimpulannya, penerapan dinding geser efektif meningkatkan kekakuan dan ketahanan struktur, dengan dinding geser bentuk I-WF menjadi yang paling optimal, menggunakan tulangan badan 2 lapis D16-150 dan tulangan elemen batas khusus D13-50.
The construction project of the Faculty of Medicine Campus 3 Campus 3 UIN Maliki Malang Phase II in Batu faces the problem of lack of an earthquake mitigation system. Therefore, this final project aims to design a Shear wall to increase the rigidity and resistance of the structure to lateral earthquake loads, in accordance with SNI 1726:2019. This quantitative study uses experimental observation simulations with ETABS software to analyze the performance of the structure, including fundamental periods, fundamental shear forces, eccentricities, deviations between levels, and the influence of P-Delta. The results showed that the addition of Shear walls could reduce displacement by up to twofold, and of the I-WF, L-Shape, and T-Shape Shapes tested, only the I-WF Shape met the eccentricity and dual system requirements of SNI 1726:2019. Although all Shapes have cracks in the lower floors that require adjustment of the stiffness modifier, the I-WF Shape has proven to be the most effective. In conclusion, the application of Shear walls effectively increases the rigidity and durability of the structure, with I-WF Shape Shear walls being the most optimal, using D16-150 2-layer body reinforcement and D13-50 special boundary element reinforcement.